4
1516
Faulty init of scaling data
No response
1517
Error during reading of the cyclic actual
values
No response
1518
Error during writing of the cyclic set val-
ues
No response
1519
Critical GDP error while initialization
Incorrect reading or writing of important data via GPD. GPD means
the communication between controller and fieldbus controller.
No response
1520
Invalid version of the controller firm-
ware
Installed controller firmware cannot be used with this type of field-
bus. Version see controller parameter P102.2 or IDN P-0-0221
No response
1521
Warning: Error while reading service
data
No response
1522
Warning: Error while writing service
data
No response
1523
Error during command execution
An error occurred during a command execution.
No response
1524
Timeout during command execution
A timeout occurred during a command execution.
No response
1525
MST-Error; drive controller lost syn-
chronization
Sercos: MST incorrect
SoE: controller signaled lost synchronization
No response
1526
Error: MDT miss twice; watchdog time-
out process data
Sercos: failure of MDT (MDT miss twice)
SoE: watchdog timeout at process data
No response
1527
Error during switch up of phase
Error during switch up of the bus state
(phase switch up)
No response
1528
Error during switch down of phase
Error during switch down of the bus state
(phase switch down)
No response
1529
Phase transition without ready
acknowledge
Sercos:
n
switch up to CP3 not possible
back to CP0.
n
switch up to CP4 not possible
back to CP0.
SoE:
n
switch up to Safe-Op not possible
back to Pre-OP.
n
switch up to Op not possible
back to Safe-OP.
No response
1530
Error: Invalid phase
Invalid phase (bus state) set.
No response
1531
Switch to non-initialized operation
mode
Switch to a not supported or unknown operation mode.
No response
1532
Error: Two drives with same address in
ring
Error message only possible using Sercos.
No response
1533
Error while reading sync data of drive
controller
Error when adjusting the synchronization data with the settings in
the drive controller.
No response
1534
Overflow mailbox service
Overflow during a fragmented mailbox service.
No response
1535
Invalid mailbox size
Error detected when checking the mailbox size.
No response
1536 to
1555: see Application Manual SoE slave for BM2500/3300/5000 (5.14010)
1609
too many repetitions with HIPER-
FACE
protocol
No response
1700
Error code directly according to error
report from encoder
Pulse block
1701
Analog signals outside of specification
Calibration data are faulty
Rotary encoder: Analog signals outside of specification
Linear encoder: Calibration data are faulty
Pulse block
1702
Internal angle offset faulty
Pulse block
1703
Table for data field partitioning
destroyed
Pulse block
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......