Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
359
3
Example 3:
Fieldbus cycle = set value cycle = 1 ms and ramp function generator cycle = 250 µs
A new calculated set value is transferred in each fieldbus cycle.
The ramp function generator is configured in the fieldbus task. It has a cycle
time of 250 µs.
Fieldbus cycle time = 1 ms and
Division ratio fieldbus
task = 4
Virt. master set value cycle time = Interpolation interval = 1 ms
1 ms / 250 µs - 1 = 3
Interpolator generates 3 interpolated set value in the ramp function generator.
Always the sum of main and additional set value will be interpolated, i.e. the value of
Input 32 bit additive is also effective at interpolation. Every change of the total
set value is immediately effective and interrupts a running interpolation if necessary.
The interpolator is implemented before the ramp function generator controller and the
ramp generator. Thus the functions of the ramp function generator remain also at active
interpolator, as e. g. limitation and polarity reversal of the input value, directional block,
ramp function generator block, ramp function generator stop, quick stop function and
ramp generator.
This interpolator must not be confused with the interpolator of the ramp function generator
cycle to controller cycle. This interpolator is specified in chapter
Interpolator active and ramp generator switched off
The ramp generator can be switched off either via
Mode bit 10 (transparency
mode) or via setting ramp times to zero (
and
). The ramp function gen-
erator operates in both cases in the "transparency mode" (output = input), i. e. the cyclical
input set values are immediately effective at ramp output.
m
Switch off via ramp times (= 0 s)
This means a stop at current limit, because the ramp-down time can be used also for
quick stop or error response ("Stop at deceleration ramp"). If this is not desired, the
stop at deceleration ramp and the quick stop time in
must be set or the trans-
parency mode via bit 10 must be used.
m
Switch off via Mode bit 10 of parameter
The ramp-up and ramp-down times can be set here as required. In case of a stop at
the deceleration ramp, it will be broken at the deceleration ramp.
The bits 8 (Ramp-up is active) and bit 9 (Ramp-down is active) in
are not
changed.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......