![Baumuller b maXX BM5800 Скачать руководство пользователя страница 669](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380669.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
669
3
133.41
Anisotropy
Display of the demodulated signal after the motor diagnosis via the electrical angle. The
increment accords to 360 degrees/256 values = 1.40625 degrees.
133.51
Saliency ratio
This parameter is necessary to set the commutation controller and it displays the ratio be-
tween Lq and Ld:
If the motor parameters are not known, the commutation controller can be set in the first
step with the default value 0.1.
133.55
Damping factor
Damping gain. The high-frequency component of the Iq-I term is multiplied by this factor
and is used as an additional speed set value.
133.58
Time constant fast damping filter
Fast time constant by which the Iq-I term is filtered.
The high-frequency component of the vibration damping is determined here.
133.59
Time constant slow damping filter
Slow time constant by which the Iq-I term is filtered.
The constant component is filtered with this.
Saliency Ratio
Lq
Ld
–
Lq
------------------------
=
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......