Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
620
3.8
145.15
Master speed set value additive 1
145.16
Master speed set value additive 2
These parameters are two additional set value inputs. The resolution is
10000 * 16 bit increments/revolution per ms.
The sum of both additional speeds (ms) is added to the internally effective master axis
position as a change of position at the function "Real master axis". The displayed master
axis position in
and
continues to show the original master axis val-
ue.
At the "Virtual master axis" function the values are added to the main set value
prior to the set value interpolation and the ramp function generator.
For the "Virtual master axis with interpolation" mode the main set value must be written,
e.g. as a cyclical set value via the fieldbus. Only if this is done the interpolation will be
started and the total set value from the three input parameters will be used.
It is not necessary to write the main set value for mode "Virtual master axis with ramp gen-
erator". Each cycle calculates the total set value. This value is written to the input of the
ramp generator.
145.18
Master angle offset
The set value of the slave axis can be set in the "Real master axis" mode with this param-
eter. The offset immediately is active.
Set value slave axis = Master axis po Angle of master axis offset
The offset operates as an absolute position set value. This means, if the same offset val-
ue is set twice, the value is not added twice. The change of the offset is always added. If
the offset is set to zero, the set value of the slave axis corresponds to set value of the
master axis.
The offset is a signed value in a 32 bit angle format. It has the resolution of the master
axis, is previously added to the gear and its sampling rate is 1 ms.
The resulting offset adjustment speed can be limited via
Virtual master speed
set value. Therewith the entire offset adjustment can be distributed to several controller
cycles.
The parameter has no function at synchronous operation with a virtual master axis.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......