Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
514
3.8
3.8.1.2 ProDrive Positioning
Figure 136:
ProDrive Positioning, general parameters
3.8.1.3 Parameter overview
Functional block:
FbPosCommonData [121]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
on
ly
St
o
ra
g
e
D
S
Su
pp
ort
Cycli
c
W
rite
Axis-
ind
epen
den
t
121.1
Positioning general
mode
WORD
0x0
0xFFFF
0x0
1:1
X
121.2
Staus limit switch
WORD
0x0
0xFFFF
0x0
1:1
X
121.3
Negative SW limit
Switch
UDINT
0
0xFFFFFFFF 0x00010000
Inc
1:1
X
121.4
Positive SW limit switch UDINT
0
0xFFFFFFFF 0xFFFF0000
Inc
1:1
X
121.5
Positioning window
UDINT
0
0xFFFFFFFF 0x1000
Inc
1:1
X
121.6
Positioning window time UINT
0
65535
10
ms
1:1
X
121.7
Feedrate override
UINT
0
65535
10000
%
100:1
X
X
121.8
Stop Delay
UDINT
7
65535
200
Inc/
ms²
100:1
X
121.9
Positioning position
actual value
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1
X
121.10
Maximum Position
Value
UDINT
0x0
0xFFFFFFFF 0xFFFFFFFF
Inc
1:1
X
121.11
Speed limit
UDINT
1
65535
3276
Inc/ms 1:1
X
O
121.12
Position actual value
revolutions with over-
flows
UDINT
0
0xFFFFFFFF 0
Inc
1:1
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......