Operation manual - EN
www.atmos.eu
EN - 76
ACD03/04
Menu
- Communication:
→
Hydraulics/Communication
(Access level - User - nothing / Service technician - everything)
The
Communication
menu is used to pair and set individual room units (devices) with the ACD 03/04
controller.
The controller allows the definition (setting) of up to 5 ARUa, ARUb, ARUc, ARUd and ARUe units
(Circuit 1, 2, 3 and 4 and DHW).
The basic concept
counts on the setting
of one room unit for one heating circuit.
Therefore,
for MK and DK circuit type after switching on the room unit (Yes), a predefined heating circuit is
automatically assigned to the relevant room unit (Circuit 1 is assigned to ARUa, Circuit 2 is assigned
to ARUb, Circuit 3 is assigned to ARUc, etc.). At the same time, the RSE room temperature sensor of
the respective unit is automatically assigned to the circuit. All provided that no other sensor and unit
have been already assigned.
The controller also allows you to set the
Room unit for more heating circuits or more room units
for one heating circuit concept in the next steps.
The setting is performed with the button (to enter the menu), under which we click on the
→
symbol for
Hydraulics
and then
Communication
.
10. Setting menu - Hydraulics
/Communication