Operation manual - EN
www.atmos.eu
EN - 178
ACD03/04
Controlled combined boiler (GSP)
connected with accumulation tanks (into series)
Example 18
- Hydraulic diagram:
77833
7
xxxx (FAN +BRE+SEKGSP - combi) + x
7
xxx (DKP+DHW+ACC) + xx
8
xx (RLA3) + xxx
3
x (MK2) + xxxx
3
(MK1)
Combined boiler controlled with a controller with manual (wood) and automatic (pellet burner) stocking
controlled on the basis two sensors on the first accumulation (buffer) tank (PF and FPF sensors).
The ACD 03/04 controller allows the burner operation (BRE) to be switched on and off as required by
the operator (for example when cleaning the boiler). Automatic start of the pellet burner after all wood
is burnt out (according to WF and AGF sensors). Switching sources - wood/pellets. It also controls the
boiler circuit pump (DKP), temperature of return water to boiler (RLA), two heating circuits (MK1,
MK2) and the tank (boiler) for DHW heating (SLP).
With this connection, the pellet burner only recharges the first accumulation tank.
INFO
- DCxxSP(X) and DCxxGSP boilers are factory equipped with installed AGF (Tsv)
and WF (Tk) sensors, which can be used (connected) to the ACD 03/04 controller.
PF2 sensor serves only to provide information on the accumulation tank temperature.
2 - 6 bar
10 – 15 °C
A25
1
2
AF
ATMOS
ACD
PF
WF
Servo
SEKGS
AGF
(TSV)
DKP
M
M
M
Max. 60°C
MK1
MK2
MKP2
MKP1
VF1
VF2
SF
Max. 50°C
ARU30
ARU10
ARU5
22,5 °c
PF2
FPF
FAN L
SLP
RLA3O
RLA3C
VF3
10. Setting menu - Hydraulics - Hydraulic diagram