Operation manual - EN
www.atmos.eu
EN - 135
ACD03/04
→
Hydraulics/Function configuration
Temperature sensors submenu - definition of additional sensors
The controller allows you to add a second outdoor sensor (AF2) for better control of heating circuits
and add additional information sensors (INFO1 to INFO5).
To activate them, set the function to
Yes
.
AF
–
outdoor temperature sensor -
basic temperature (information) for control of heating
circuits. It is automatically defined when defining the function of heating circuits with
equithermal control (NTC 20 kΩ sensor required). Inputs AF, VI4 and VI5 are recommended
for the outdoor temperature sensor.
AF2
–
additional outdoor sensor -
second outdoor temperature sensor (on the other side of the
house). It allows you to use the average outdoor temperature calculated from AF and AF2
values.
INFO1 to INFO5
–
information temperature -
information sensors 1 to 5 can be used to
measure information temperatures that do not affect any of the functions.
10. Setting menu - Hydraulics
/F
unction configuration/T
emperature sensors