Operation manual - EN
www.atmos.eu
EN - 132
ACD03/04
- KLV/KVLF2
–
solar panel switch -
is intended for the installation of solar panels
with different gains depending on the movement of the sun (morning/afternoon,
installation on the eastern/western side of the roof). The switch evaluates the situation
and activates the solar panel with the greatest gain.
- KRLF
–
solar return -
sensor of return temperature from the solar tank (NTC 20 kΩ
sensor) - sensor is used for more accurate calculation of solar gain - for parameters see
→
SOLAR menu.
- SLV/SLVF
–
solar tank switch -
is intended to switch between 2 solar tanks (e.g. a
bivalent DHW tank and an accumulation tank, or 2 DHW tanks, etc.)
The tank with
SLVF sensor is charged as a priority.
- SZV
–
solar losses valve -
function is intended in case of the solar circuit overheating
to open the valve and remove excess energy (release of pressure).
KLVF
SOLP
KSPF
M
KVLF
SOLP
KSPF
KLV
KVLF2
M
KVLF
SOLP
KSPF
SLV
SLVF
M
KVLF
SOLP
KSPF
KLV
KVLF2
M
SLV
SLVF
1
- KVLF + KSPF + SOLP
Basic functions n
KLV/KVLF2 extension
SLV/SLVF extension
KLV/KVLF2 + SLV/SLVF extension
2
- KVLF + KSPF + SOLP + KLV/KVLF2
3
- KVLF + KSPF + SOLP + SLV/SLVF
4
- KVLF + KSPF + SOLP + KLV/KVLF2 + SLV/SLVF
10. Setting menu - Hydraulics
/F
unction configuration/Solar heating
Содержание ACD 03
Страница 1: ...Operation manual EN www atmos eu EN 1 ACD03 04 Operation manual ...
Страница 2: ...Operation manual EN www atmos eu ACD03 04 ...
Страница 8: ...Operation manual EN www atmos eu EN 8 ACD03 04 ...
Страница 265: ...Operation manual EN www atmos eu EN 265 ACD03 04 12 Overview of menus and their parameters ...