Operation manual - EN
www.atmos.eu
EN - 115
ACD03/04
10. Setting menu - Hydraulics
/F
unction configuration/Heating circuit 2 function
Control circuit connection -
activation of circuit connection
- Yes / No
- the button allows you to activate or deactivate the function of connecting the heating
circuit to another heating circuit, which allows their joint control.
To activate control circuit connection, switch it on =
Yes
Go a step back by clicking on the symbol
and set - Circuit connection type.
RL2 – return water sensor from heating circuit 2
(NTC 20 kΩ sensor) - sensor ensures
shutdown of the heating circuit (pump) at a small temperature gradient between the outlet
and return from the heating system (e.g. 2 K) (
→
P17
Heating circuit
parameter).
2 - 6 bar
10 – 15 °C
A25
1
2
M
AF (4)
ATMOS
ACD
22,5 °c
ARU30
(31-34)
Max. 60 °C
PF (15)
FPF
(VI3 - 21)
RL2
WF (5)
VA2
(46,47)
(servo)
AGF
(13)
(TSV)
DKP (59)
RS(E)2 – room sensors -
the function is used to
adjust
the assignment of sensors of
ARU10
and ARU30
room units
(RSEb (a, c, d, e)) for heating circuit 2
or to activate (assign)
ARU5
room unit (sensors) -
RSb (a, c, d)
) for heating circuit 2.
RSb (a, c, d) sensor name -
allows custom naming of the room unit (sensor)
ARU5
after
its activation.
The name of the room unit (sensor) is then displayed in the controller in
Information
i
(Group - Room temperatures).