ACD03/04
→
Hydraulics/Function configuration
Boiler
submenu- definition of additional functions for the boiler
:
FAN
–
exhaust boiler fan -
the function is based on the boiler type set in the
Installation
Guide
(Wizard). As standard, it is the exhaust boiler fan that removes the flue gases from
the boiler. However, some boilers use a PRESS pressure fan (e.g. ATMOS DC100, DC70S),
see the following functions.
The fan is operated by the button (hand) on the controller display. When the boiler is
cold, start the fan for firing up by pressing the button with the (hand) symbol.
The time for
firing up
a boiler with manual stoking is factory-set to the maximum of 60
minutes (P08
Boiler
parameter). The controller remains in
firing up
mode until it reaches the
minimum flue gas temperature
defined in P18
Boiler
parameter. If the minimum flue gas
temperature is not reached, the boiler (fan) will be shut down.
During boiler operation, the fan is controlled automatically according to the water
temperature (WF sensors) set in the Boiler menu. When the temperature defined by P02
Boiler
parameter is reached, the fan is switched off, when the boiler water temperature drops by
the difference defined by P06
Boiler
parameter, it is switched on again.
When all fuel is burnt out
(defined by the flue gas temperature - lower than P18
Boiler
parameter),
the fan
(boiler circuit pump - according to P17
Boiler
parameter setting)
is shut
down
.
INFO
- Always
start the
exhaust boiler fan
before
opening
the door (e.g. when stoking)
with the (hand) button for the time specified by P09
Boiler
parameter.
10. Setting menu - Hydraulics
/F
unction configuration/Boiler
Содержание ACD 03
Страница 1: ...Operation manual EN www atmos eu EN 1 ACD03 04 Operation manual ...
Страница 2: ...Operation manual EN www atmos eu ACD03 04 ...
Страница 8: ...Operation manual EN www atmos eu EN 8 ACD03 04 ...
Страница 265: ...Operation manual EN www atmos eu EN 265 ACD03 04 12 Overview of menus and their parameters ...