Operation manual - EN
www.atmos.eu
EN - 162
ACD03/04
Controlled boiler with burner
connected with accumulation (buffer) tank
Example 10
- Hydraulic diagram:
27833
2xxxx (BRE - boiler with burner) + x7xxx (DKP+DHW+ACC) + xx8xx (RLA3) + xxx3x (MK2) + xxxx3 (MK1)
Automatic pellet boiler controlled by the controller based on two sensors on the accumulation (buffer)
tank (PF and FPF).
The ACD 03/04 controller allows the burner operation (BRE) to be switched on and off as required
by the operator (for example when cleaning the boiler). It controls the boiler circuit pump (DKP),
temperature of return water to boiler (RLA), two heating circuits (MK1, MK2) and the tank (boiler)
for DHW heating (SLP).
The operation of the boiler fan is controlled from the ATMOS A25 pellet burner.
M
M
Max. 60 °C
PF
FPF
Max. 50°C
MK1
MK2
MKP2
MKP1
VF1
VF2
SF
WF
AF
ATMOS
ACD
22,5 °c
ARU30
DKP
M
ARU10
ARU5
Tk
A25
R
Tsv
BRE
SLP
RLA3O
RLA3C
VF3
10. Setting menu - Hydraulics - Hydraulic diagram