Operation manual - EN
www.atmos.eu
EN - 223
ACD03/04
• P09
Sources
parameter- EHP comfort operation
The parameter is intended to set up the method of heating circuits operation when using EHP
accumulation tank electric heating.
Factory default setting: On
Setting options:
On -
EHP electric heating (electric coil) of the accumulation tank is a fully operational source
of energy like any boiler.
The circuits operate according to the requirements of each circuit
Off -
EHP electric heating (electric coil) of the accumulation tank serves permanently
only as anti-freeze protection defined by
→
P08
Heating circuit
parameter and
→
P14
Accumulation tank
parameter. The circuits only work in
Setback
mode.
INFO
- P09
Source
s, P10
Source
and P11
Source
parameters are visible only after activation of the
function of the electrical heating of the EHP accumulation tank.
• P10
Sources
parameter - DHW summer heating using EHP
The parameter is intended to set the method of operation of the EHP accumulation tank during the
summer heating of DHW.
Factory default setting: Off
Setting options:
On -
in case of a requirement for DHW heating in the summer, the EHP electric heating
(electric coil) in the accumulation tank
will be
switched on.
Off -
in case of a requirement for DHW heating in the summer, the EHP electric heating
(electric coil) in the accumulation tank
will not be
switched on.
INFO
- P09
Source
s, P10
Source
and P11
Source
parameters are visible only after activation of the
function of the electrical heating of the EHP accumulation tank.
10. Setting menu - Sources