Basic description of operating modes
- When the mode is set to
StandBy
, all heating, domestic hot water (DHW), solar, etc.
functions of the controller are switched off. The controller only provides frost protection .
- When the mode is set to
Setback
, the controller permanently maintains the
economic
temperature
for the relevant heating circuit.
- When the mode is set to
Comfort
, the controller permanently maintains the
comfort
temperature
for the relevant heating circuit.
- When the mode is set to
Summer
, the controller only provides domestic hot water (DHW).
Heating circuits are switched off. (The function is only available if the DHW circuit mode
connection to a heating circuit is set (
→
Hydraulics / Function configuration / Heating
circuit function / Control circuit connection = Yes)
- When the mode is set to
Auto
, the controller maintains predefined temperatures (Comfort
/ Setback) depending on the setting of the time (weekly) programs.
For
Auto
mode, you can select the type of weekly program. You can choose from two
different weekly program options (one-week / three-week A - B - C), according to previous
custom settings.
- When the mode is set to
Visit
, the controller temporarily maintains the
Comfort
temperature for a preset period of time.
Therefore, for
Visit
mode, it is necessary to set the mode duration period (hours, minutes),
after which the originally set mode and temperature is reset.
- When the mode is set to
Absence
, the controller temporarily maintains the
Economic
(Setback)
temperature for a preset period of time.
Therefore, for
Absence
mode, it is necessary to set the mode duration period (hours,
minutes), after which the originally set mode is reset.
- When the mode is set to
Holiday
, the controller remains in
StandBy
mode with frost
protection (unless set otherwise - Economic mode) for a preset period of time (depending on
its setting, e.g. frost protection temperature).
Therefore, for mode
Holiday
, it is necessary to set the mode period (days), for which the
room unit shall remain in that mode.
INFO
- Temporary modes are most often used as a non-recurring change, after which the
system returns to
Auto
mode .
8. Operating modes menu
Содержание ACD 03
Страница 1: ...Operation manual EN www atmos eu EN 1 ACD03 04 Operation manual ...
Страница 2: ...Operation manual EN www atmos eu ACD03 04 ...
Страница 8: ...Operation manual EN www atmos eu EN 8 ACD03 04 ...
Страница 265: ...Operation manual EN www atmos eu EN 265 ACD03 04 12 Overview of menus and their parameters ...