Operation manual - EN
www.atmos.eu
EN - 140
ACD03/04
Key to define hydraulic diagram number
BOILER type
DKP / ACC / TUV
CIRCUITS
Circuit 3
Circuit 2
Circuit 1
X
x x x x
x
X
x x x
x x
X
x x
x x x
X
x
x x x x
X
without boiler =
0
no function =
0
no function =
0
no function =
0
no function =
0
NOT CONTROLLED
=
1
Boiler with its own controller
(the controller does not control
the boiler)
DKP =
1
Boiler circuit pump
DK3 =
1
Heating circuit
Direct unmixed
DK2 =
1
Heating circuit
Direct unmixed
DK1 =
1
Heating circuit
Direct unmixed
BRE =
2
Automatic boiler with burner
DHW =
2
Domestic hot water
EK =
2
*
(ONLY xxxx2 or xxx2x or xx2xx)
External boiler
FAN =
3
Boiler with manual stoking
and exhaust fan
DKP + DHW =
3
Boiler circuit pump and
Domestic hot water
MK3 =
3
Heating circuit
Mixed according to outdoor
temperature (equitherm/actuator)
**(NOT POSSIBLE WITH
SEKGSE, SEKGSP)
MK2 =
3
Heating circuit
Mixed according to outdoor
temperature (equitherm/actuator)
MK1 =
3
Heating circuit
Mixed according to outdoor
temperature (equitherm/actuator)
PRESS =
4
Boiler with manual stoking
and pressure fan
ACC =
4
Accumulation tank
DHW2 =
4
Heating of the second domestic
hot water tank (DHW)
-
-
FAN + SEKGSE =
5
Boiler with manual stoking,
exhaust fan and servo flap
(GSE)
DKP + ACC =
5
Boiler circuit pump and
accumulation tank
SOL =
5
Solar heating
-
-
FAN + BRE =
6
Combined boiler with
exhaust fan and burner
(SP / boilers with modification
for pellet burner)
DHW + ACC =
6
Domestic hot water and
accumulation tank
KR3 =
6
Heating circuit
Mixed with constant (fixed)
temperature with source
requirement
**(CANNOT BE USED
WITH SEKGSE, SEKGSP)
KR2 =
6
Heating circuit
Mixed with constant (fixed)
temperature with source
requirement
KR1 =
6
Heating circuit
Mixed with constant (fixed)
temperature with source
requirement
FAN + BRE + SEKGSP =
7
Combined boiler with
exhaust fan and burner and
servo flap (GSP)
DKP + DHW + ACC =
7
Boiler circuit pump,
domestic hot water and
accumulation tank
FR3 =
7
Heating circuit
Mixed with fixed temperature
without requirement for source
**(CANNOT BE USED
WITH SEKGSE, SEKGSP)
FR2 =
7
Heating circuit
Mixed with fixed temperature
without requirement for source
FR1 =
7
Heating circuit
Mixed with fixed temperature
without requirement for source
-
-
RLA3 =
8
Mixed return temperature to
the boiler
RLA2 =
8
Mixed return temperature to
the boiler
RLA1 =
8
Mixed return temperature to
the boiler
***Custom Definition
=
9
***Custom Definition
=
9
***Custom Definition
=
9
***Custom Definition
=
9
***Custom Definition
=
9
The boiler type is defined according to the selection in the setup wizard after the first start of the controller.
* The EK function can only be defined by default for one circuit (output).
** The pump terminals of MK, KR and FR mixed circuits are assigned in circuit 3 in the hydraulic connection of the boiler with the
SEKGSE and SEKGSP servo flap. The function is not supported by the hydraulic diagram number (cannot be set up). Moving the
MKP3, KRP3 or FRP3 pump to another terminal is possible using your own definition during manual configuration.
*** If during the first configuration of the controller (Wizard) the number of a specific function cannot be defined, set the
number 0
to
the relevant position. After completion of the configuration wizard, enter the
Hydraulics
menu and then the
Function configuration
menu and manually set (adjust) the required function for the boiler and the mixed (heating) circuit. If the manually defined function
does not correspond to any function (number) in the key (table) of the hydraulic diagram, the
number 9
is automatically entered in the
hydraulic diagram number.
10. Setting menu - Hydraulics - Hydraulic diagram