ACD03/04
the same function as pressing the button (hand symbol) of the ACD03/04 controller, it only
switches the boiler fan on or off according to the boiler function logic.
ATTENTION
- For combined boilers (DCxxSP(X), CxxSP, DCxxGSP - type 6, 7), the
BTN (BTNH) button function only works in boiler mode with manual stoking (as for 3, 5
type). However, the BTN (BTNH) button has no connection to the boiler burner (long press
of the button only invokes a secondary function on the controller display).
The burner
must always be switched off on the ACD03 controller display.
PAV
–
boiler operation output -
output (230V) of the turned on boiler - e.g. boiler operating
hours counter (in operation mode), output for boiler failure alarm, etc.
Output closed when the condition of operation of the boiler fan is met and the boiler
operating temperature is reached..
DKP
–
boiler circuit pump
- pump is controlled according to the settings (P17
Boiler
parameter)
- according to the WF boiler water temperature
- according to the AGF flue gas temperature
- according to the BRE burner function
- according to the temperature in the upper part of the accumulation tank (PF)
For DKP function, additional function can be activated:
PLP – zone valve
- a function (valve) can be added to the boiler circuit. This function
separates the boiler circuit from the accumulation tank, if the boiler pump is switched
off and the minimum operating temperature of the boiler is not reached. This provides
protection against unintentional cooling of the accumulation tank via the boiler (do not
use the function with the boiler return water control function - RLA)
PLP output type - NO -
zone valve without electric current open
PLP output type - NC -
zone valve without electric current closed
M
M
VF1 (9)
VF2 (11)
MKP2 (56)
MKP1 (53)
MK1 (40,41) MK2 (43,44)
Max. 50 °C
SF (7)
Max. 60°C
2 - 6 bar
10 - 15 °C
WF (5)
PF (15)
AF
(4)
ATMOS
ACD
ARU30
(31-34)
ARU10
(31-34)
ARU5
(VIx)
22,5 °c
AGF (13)
FAN L (70)
DKP
SLP (62)
VI1 (17)
(KVLF)
VA3 (37)
(SOLP)
VI2 (19)
(KSPF)
PLP
10. Setting menu - Hydraulics
/F
unction configuration/Boiler
Содержание ACD 03
Страница 1: ...Operation manual EN www atmos eu EN 1 ACD03 04 Operation manual ...
Страница 2: ...Operation manual EN www atmos eu ACD03 04 ...
Страница 8: ...Operation manual EN www atmos eu EN 8 ACD03 04 ...
Страница 265: ...Operation manual EN www atmos eu EN 265 ACD03 04 12 Overview of menus and their parameters ...