Operation manual - EN
www.atmos.eu
EN - 191
ACD03/04
• P02
System
parameter- Enabling planning of weekly programs
The parameter is used to set options for using time programs in one week (A) or one to three
weeks (A, B, C). The setting for 1 week (A) is used where we want the same program every week
without exception (one-week program). Settings A, B, C is used where we need to set three (3)
different consecutive programs, e.g. for 3 shift operation (morning / afternoon / night), or to distin-
guish working week / holiday or holiday week / illness, etc. When selecting A, B, C, the program
A, B or C program selection is always offered when programming time programs (see Fi Time
programs menu), where the user selects the required weekly program.
INFO -
When setting (activating)
Auto
mode, the controller always asks what weekly
program the user wants (applies to setting
→
P02
System
parameter to A, B, C). Setting
and check of time programs is performed in the
0
24
Time programs submenu under the
button.
• P04
System
parameter - Temperature of transition to summer mode
If the average outdoor temperature exceeds the value of this parameter, the heating will end and
the transition to summer mode occurs. When the temperature drops below the set value minus 1 K,
the heating is started again
INFO -
The average temperature is calculated according to the type of construction: heavy
- 24 hours / medium 8 hours / light - 2 hours (
→
P10
System
parameter).
Switching the controller off and on resets the average temperature (immediate change).
Factory default setting:
20 °C
10. Setting menu - System
Содержание ACD 03
Страница 1: ...Operation manual EN www atmos eu EN 1 ACD03 04 Operation manual ...
Страница 2: ...Operation manual EN www atmos eu ACD03 04 ...
Страница 8: ...Operation manual EN www atmos eu EN 8 ACD03 04 ...
Страница 265: ...Operation manual EN www atmos eu EN 265 ACD03 04 12 Overview of menus and their parameters ...