Hydraulics/Function configuration
General setting
submenu - definition of additional functions:
The controller allows you to activate and use (if there are free inputs and outputs) additional functions.
To activate them, set the function to
Yes
.
SME
–
external alarm (input) -
is connected to voltage-free inputs (except for DVI1, DVI2) -
if the input is closed (short-circuited), an alarm is switched on.
The function can be used as an input connected to a Home Security Alarm or CO Alarm.
Subsequently, the alarm is signaled on the ACD03/04 controller display and the ARU30
room units in
i
Information.
SMEH
–
external alarm (input) -
is connected to DVI1, DVI2 voltage inputs - if the input is
closed (under voltage), an alarm is switched on.
The function can be used, for example, to display alarm information from the ATMOS A25,
A45 and A85 pellet burner from R reserve outputs (R2, R5, R6).
ELH
–
summer mode output -
at the moment of switching to summer mode, the output is
permanently closed. The function can be used, for example, to switch on the electric boiler
for DHW heating.
PP
–
output of circuits demand
- at the moment of heating circuits demand, the output is
closed.
The output is switched off with a delay after the demand is canceled, see
→
General
setting menu - P01
General setting
parameter.
The function can be used to open the backup energy supply for heating the building (for
example, district heating).
10. Setting menu - Hydraulics
/F
unction configuration/General setting