Operation manual - EN
www.atmos.eu
EN - 271
ACD03/04
Permanent mode - SETBACK (ECONOMIC) (night)
In this mode, the heating circuit is permanently regulated to the Setback (attenuation) temperature
(night) set in the ACD03/04, taking into account the position of the rotary knob (temperature correction).
Temperature correction is active when the diode is permanently on.
LED indication
Operating mode
Automatic mode with permanent correction - AUTO
Automatic mode with temporary correction
Permanent mode - COMFORT (day)
Permanent mode - SETBACK (night)
Visit - temporary COMFORT temperature (set in ACD 03/04)
Absence - temporary SETBACK temperature (set in ACD 03/04)
Holiday - temporary STBY - anti-freeze/permanent attenuation (set in ACD 03/04)
STBY - Standby mode
The ARU10 unit is properly paired, but the control is not assigned to any circuit
Unit not paired / COMMUNICATION failure = flash of all LEDs 1x / min
The modes in the gray field set in the ACD03/04 controller
- LED indicator is on
- LED indicator is flashing
ATTENTION:
If the diode is flashing under two symbols at the same time, the room unit
is in the special mode ( - - ) and temperature correction is active depending on the
rotary knob setting. This modes can only be set on ACD 03/04.
If the LED flashes in any operating mode, this is a condition without taking into account
the position of the rotary knob (without temperature correction). To make correction active
it is enough to turn rotary knob more than 0,5 K or briefly press the button .
ADDRESSING THE BUS - PAIRING WITH ACD 03/04
After connecting the room unit to the communication line (four-wire cable), it is necessary to add the
room unit to the list of devices on the line. This is done by pairing the connected product (room unit)
with the ACD 03/04 controller.
The regulation allows
several ways of pairing
, so choose the one that is most advantageous for us
(see the instruction for use of ACD 03/04 controller).
INFO
- If the unit is not correctly paired with ACD 03/04, all LEDs still on.
13. R
oom units
Содержание ACD 03
Страница 1: ...Operation manual EN www atmos eu EN 1 ACD03 04 Operation manual ...
Страница 2: ...Operation manual EN www atmos eu ACD03 04 ...
Страница 8: ...Operation manual EN www atmos eu EN 8 ACD03 04 ...
Страница 265: ...Operation manual EN www atmos eu EN 265 ACD03 04 12 Overview of menus and their parameters ...