Operation manual - EN
www.atmos.eu
EN - 247
ACD03/04
10. Setting menu - Solar heating
• P10
Solar heating
Parameter - Solar gain RESET (zeroing)
The parameter is intended to reset (zero) solar gains over a certain period of time.
INFO -
Reset by confirming the
Yes
command.
• P11
Solar heating
parameter - Solar circuit flow value
The parameter is intended to adjust the flow of the solar circuit, which is necessary for the
calculation of the solar gain (
→
P09
Solar heating
parameter).
Factory default setting:
0,1 l/min
• P12
Solar heating
parameter - Media density
The parameter is intended to define the density of the liquid in the solar circuit (according to
the manufacturer's data), which is necessary for the correct calculation of the solar gain (
→
P09
Solar heating
parameter).
Factory default setting:
1.05 kg/l
• P13
Solar heating
parameter - Thermal media capacity
The parameter is intended to define the thermal capacity of the liquid in the solar circuit (according
to the manufacturer's data), which is necessary for the correct calculation of the solar gain (
→
P09
Solar heating
parameter).
Factory default setting:
3.6 kJ/kgK
• P14
Solar heating
parameter - Solar panel shutdown temperature
The parameter is intended to activate the protection of the solar circuit (switching off the SOLP
pump), if the temperature of the solar panel media is too high.
Factory default setting:
Off
CAUTION
- When this protection is switched on, set the maximum safe temperature of the
solar panel.