Operation manual - EN
www.atmos.eu
EN - 82
ACD03/04
ATTENTION
- Each device (ARU10, ARU30, other devices) is
slightly different, so it
requires a different pairing procedure!
INFO
- The pairing
process can be interrupted
on the ACD 03/04 controller (
→
Hydraulics / Communication) by clicking the
Pairing
button again (the time countdown
disappears).
ATTENTION
-
If the current room temperature is not displayed
on the ARU30 room
unit, this means that the sensor of the selected room unit is not assigned to the relevant
heating circuit.
The assignment is performed in the submenu
→
Hydraulics / Function configuration /
Heating circuit function / RS(E)x - Room sensors -
RSa (b, c) and RSEa (b, c, d, e)
.
RSa (b, c)
button - for
ARU5
room unit (sensor)
RSEa (b, c, d, e)
button - for
ARU10 and ARU30
room units (external room temperature
sensor).
Update -
The button is used to update the program in the room unit using the SW program stored on
the SD card in the controller.
The update is performed only by the Service Technician in necessary cases (new SW version,
malfunctions, etc.)
.
INFO
- For the
ARU10
room unit, the
update takes 30 s
and is signaled on the room unit
by simultaneous flashing of the 1
st
and 2
nd
LEDs or the 3
rd
and 4
th
LEDs.
For the
ARU30
room unit, the update
takes a longer time
and depends on the length of the wires.
10. Setting menu - Hydraulics
/Communication