![Atmos ACD 03 Скачать руководство пользователя страница 216](http://html.mh-extra.com/html/atmos/acd-03/acd-03_operation-manual_3003627216.webp)
Operation manual - EN
www.atmos.eu
EN - 216
ACD03/04
Accumulation tank
(Access level - User - nothing / Service technician - everything)
The setting is performed with the button (to enter the menu), under which click on the symbol
for
Accumulation tank
.
Accumulation tank
menu is used to set the parameters associated with the operation and possible use
of the accumulation (buffer) tank.
Parameters:
• P01
Accumulation tank
parameter - PFmin minimum temperature
The parameter is intended to set the temperature of the accumulation tank measured by the PF
sensor, at which the heating circuits and the DHW heating circuit are disabled (switched off) when
all useful energy is depleted.
CAUTION
- The function is active if
→
P10
Accumulation tank
parameter = 1
- accumulation
and the protection of the accumulation tank, when discharging
→
P08
Accumulation tank
parameter =
On, is On.
Circuit operation is re-enabled (switched on), when the temperature in the accumulation
tank rises by the value defined in
→
P04
Accumulation tank
parameter
.
INFO -
This is to protect the accumulation tank against complete discharge (cooling).
Factory default setting:
40 °C
10. Setting menu - A
ccumulation tank
Содержание ACD 03
Страница 1: ...Operation manual EN www atmos eu EN 1 ACD03 04 Operation manual ...
Страница 2: ...Operation manual EN www atmos eu ACD03 04 ...
Страница 8: ...Operation manual EN www atmos eu EN 8 ACD03 04 ...
Страница 265: ...Operation manual EN www atmos eu EN 265 ACD03 04 12 Overview of menus and their parameters ...