Operation manual - EN
www.atmos.eu
EN - 160
ACD03/04
Controlled boiler with burner
connected without accumulation (buffer) tank
Example 9
- Hydraulic diagram:
23333
2
xxxx (BRE - boiler with burner) + x
3
xxx (DKP+DHW) + xx
3
xx (MK3) + xxx
3
x (MK2) + xxxx
3
(MK1)
Automatic pellet boiler controlled by the controller based on the boiler temperature (WF sensor).
The ACD 03/04 controller allows the burner operation (BRE) to be switched on and off as required by
the operator (for example when cleaning the boiler). It controls the operation of the pump in the boiler
circuit (DKP) (Laddomat / thermoregulation valve), three heating circuits (MK1, MK2, MK3) (mixed
equithermal) and the accumulation tank (boiler) for DHW heating (SLP).
The operation of the boiler fan is controlled from the ATMOS A25 pellet burner.
M
Max. 60 °C
B
A
WF
Max. 50 °C
MK1
MKP1
VF1
SF
Tk
Tsv
A25
R
AF
ATMOS
ACD
ARU30
22,5 °c
DKP
M
VF2
ARU10
M
MKP3
VF3
ARU5
MK2
MK3
MKP2
SLP
BRE
10. Setting menu - Hydraulics - Hydraulic diagram