PF temperature sensor in the upper part of the accumulation tank or SF temperature sensor in the
combined DHW heater inserted as deep as possible in the pocket.
The PF sensor must always be at least 10 cm below the pipe entry into the tank.
It is not recommended to place (attach) the sensor on the pipe due to the proper functioning of the
controller!!!
FPF temperature sensor in the lower part of the accumulation tank inserted as deep as possible in the
pocket.
The FPF sensor must always be at least 10 cm above the pipe entry (outlet) to the tank.
It is not recommended to place (attach) the sensor on the pipe due to the proper functioning of the
controller!!!
Additional sensor behind the mixing valve measuring the temperature of water flowing into the
heating circuit.
4. Installation in boiler