Operation manual - EN
www.atmos.eu
EN - 200
ACD03/04
Boiler
(Access level - User - P37, P38 / Service technician - everything)
The setting is performed with the button (to enter the menu), under which click on the symbol
for Boiler.
The
Boiler
menu is used to set parameters related to the boiler (main source).
Parameters:
• P02
Boiler
parameter - KTmin minimum boiler operating temperature
The parameter is used to set the minimum operating temperature of the boiler measured by the WF
sensor. However, the actual boiler temperature may be higher, depending on the highest demand
of the heating system.
Factory default setting: 85 °C
Recommended setting:
Boilers without accumulation tank 80 °C
Boilers with accumulation tank 90 °C
INFO
- When the required (calculated) temperature is exceeded, the boiler (fan / burner)
controlled by the controller is switched off, when the boiler water temperature drops by the
difference given by
→
P06
Boiler
parameter, the boiler (fan / burner) is switched on again.
Applies to type 2 to 7 heat sources.
CAUTION
- Always place the WF sensor in a sump located on the boiler.
10. Setting menu - Boiler