![Atmos ACD 03 Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/atmos/acd-03/acd-03_operation-manual_3003627038.webp)
Operation manual - EN
www.atmos.eu
EN - 38
ACD03/04
Automatic switching
(
→
P23
Boiler
Parameter =
2- automatically
) - switching from
manual
heating
(stocking)
to automatic heating
with burner always
occurs always
after wood burns out,
when the flue gas temperature drops below the AGFmin minimum flue gas temperature defined by
→
P18
Boiler
Parameter. Operation of the burner (immediate start) depends on the requirement of the
heating system.
INFO -
If the burner was previously disabled ( - the symbol is lit in red), then its operation
will remain disabled even after switching the source.
ATTENTION
- In order to start the burner (BRE), the limit switch on the boiler hood must
be pressed (blue button next to the upper door).
7. Buttons and information on the screen