ACD03/04
Alarms
(Access level - User - everything / Service technician - everything)
The setting is done with the button (to enter the menu), under which click on the symbol for Alarms.
Alarms
menu is used to display the last 20 error messages:
logical
(e.g. failure to reach DHW temperature, exceeding the recommended flue gas
temperature, etc.)
system
(sensor error, etc.).
Alarms are displayed with date and time in the order in which the most recent alarm is displayed first
(at the top).
• Types of ALARMS:
Logical -
alarms issued due to non-compliance of a function
System -
alarms caused by a fault in the connected devices or the controller.
Sensor alarms -
sensor values are not in its measuring range. Interruption (index 0) or
short-circuiting (index 1) of the sensor (conductor).
Communication alarms
Controller alarms
Device in the network alarms
• Delete all alarms
Delete all alarms by confirming the
Yes
command. Deletion can only be done at the level of OEM
technician or manufacturer.
10. Setting menu - Alarms