SS1ES
−
01
−
SERVICE SPECIFICATIONS
SFI
SS
−
11
134
Author:
Date:
1996 LAND CRUISER (RM451U)
SFI
SERVICE DATA
Fuel pressure
regulator
Fuel pressure
at no vacuum 265
−
304 kPa (2.7
−
3.1 kgf/cm
2
, 38
−
44 psi)
Fuel pump
Resistance
at 20
°
C (68
°
F) 0.2
−
3.0
Ω
Injector
Resistance
at 20
°
C (68
°
F)
Injection volume
Difference between each cylinder
Fuel leakage
13.4
−
14.2
Ω
69
−
88 cm
3
(4.2
−
5.4 cu in.) per 15 sec.
5 cm
3
(0.3 cu in.) or less
1 drop or less per 12 min.
MAF meter
Resistance (THA
−
E2)
at
−
20
°
C (
−
4
°
F)
at 0
°
C (32
°
F)
at 20
°
C (68
°
F)
at 40
°
C (104
°
F)
at 60
°
C (140
°
F)
at 80
°
C (176
°
F)
10
−
20 k
Ω
4
−
7 k
Ω
2
−
3 k
Ω
0.9
−
1.3 k
Ω
0.4
−
0.7 k
Ω
0.2
−
0.4 k
Ω
Throttle body
Throttle body fully closed angle
Dashpot setting speed
Throttle opener setting speed
6°
2,200
±
300 rpm
700
−
1,000 rpm
Throttle position
sensor
Clearance between stop screw and lever
0 mm (0 in.)
VTA
−
E2
0.50 mm (0.020 in.)
IDL
−
E2
0.75 mm (0.030 in.)
IDL
−
E2
Throttle valve fully open
VTA
−
E2
−
VC
−
E2
0.2
−
5.7 k
Ω
2.3 k
Ω
or less
Infinity
2.0
−
10.2 k
Ω
2.5
−
5.9 k
Ω
IAC valve
Resistance (B1
−
S1 and S3, B2
−
S2 and S4)
at cold (
−
10
−
50
°
C (
−
50
−
122
°
F))
at hot (50
−
100
°
C (122
−
212
°
F))
15
−
25
Ω
20
−
30
Ω
Fuel pump resistor Resistance
at 20
°
C (68
°
F) 0.70
−
0.76
Ω
VSV for fuel pres-
sure control
Resistance
at 20
°
C (68
°
F) 37
−
44
Ω
ECT sensor
Resistance
at
−
20
°
C (
−
4
°
F)
0
°
C (32
°
F)
20
°
C (68
°
F)
40
°
C (104
°
F)
60
°
C (140
°
F)
80
°
C (176
°
F)
10
−
20 k
Ω
4
−
7 k
Ω
2
−
3 k
Ω
0.9
−
1.3 k
Ω
0.4
−
0.7 k
Ω
0.2
−
0.4 k
Ω
EGR gas temp
sensor
Resistance
at 50
°
C (122
°
F)
at 100
°
C (212
°
F)
150
°
C (302
°
F)
64
−
97 k
Ω
11
−
16 k
Ω
2
−
4 k
Ω
Heated oxygen
sensor
Heater coil resistance
at 20
°
C (68
°
F) 11
−
16
Ω
Fuel cut rpm
Fuel return rpm
1,200 rpm