14.12
Set up drives
14.12.1
Overview
Up to 21 connections to so-called logical drives (data carriers) can be configured. These drives
can be accessed in the "Program manager" and "Startup" operating areas.
The following logical drives can be set up:
● USB interface
● Network drives
● CompactFlash card
● CompactFlash card of the NCU, only for SINUMERIK Operate in the NCU (for 840D sl)
● Local hard disk of the PCU, only for SINUMERIK Operate on the PCU (for 840D sl)
Software option – for 840D sl
In order to use the CompactFlash card as a data carrier, you require the option
"Additional HMI user memory on CF card of NCU" (not for SINUMERIK Operate on
PCU/PC).
Software option – for 828D
You will need the "Manage network drives" option to manage additional drives via
Ethernet.
Note
The USB interfaces of the NCU are not available for SINUMERIK Operate and can therefore
not be configured (for 840D sl).
14.12.2
Setting up drives
The "Set Up Drives" window is available in the "Start-up" operating area for configuring the
softkeys in the Program Manager.
Note
Reserved softkeys
Softkeys 4, 7 and 16 are not available to be freely configured.
Machine manufacturer
Please refer to the machine manufacturer's specifications.
Managing programs
14.12 Set up drives
Milling
776
Operating Manual, 08/2018, 6FC5398-7CP41-0BA0