No signal flow
Gray
No network executed
Gray
STOP operating state
Gray
Procedure
1.
The program block view is open.
2.
Press the "Program stat." softkey to display the program status display
in the status display.
3.
Press the "Program stat." softkey again to hide the program status display
in the status display again.
23.5.5
Changing the address display
You can choose between specification in absolute or symbolic address.
Elements for which there are no symbolic identifiers are automatically displayed with absolute
identifiers.
Procedure
1.
The program block view is open.
2.
Press the "Symbol. address" softkey.
The list of operands is displayed sorted according to symbolic address.
3.
To return to the display showing the absolute addresses press the "Sym‐
bol. address" softkey again.
23.5.6
Enlarging/reducing the ladder diagram
You can enlarge or reduce the representation of the ladder diagram.
Edit PLC user program (828D only)
23.5 View of the program blocks
Milling
910
Operating Manual, 08/2018, 6FC5398-7CP41-0BA0