23.4
Displaying and editing PLC signals in the status list
PLC signals are displayed and can be changed in the "PLC Status List" window.
The following lists are shown
Inputs (IB)
Bit memories (MB)
Outputs (QB)
Variables (VB)
Data (DB)
Setting the address
You can go directly to the desired PLC address to monitor the signals.
Editing
You can edit the data.
Procedure
1.
Select the "Commissioning" operating area.
2.
The Ladder editor is open.
3.
Press the "Status list” softkey.
The "Status List" window appears.
4.
Press the "Set address" softkey.
The "Set Address" window appears.
5.
Activate the desired address type (e.g. DB), enter the value and press
the "Accept" softkey.
The cursor jumps to the specified address.
6.
Press the "Change" softkey.
The "RW" input field can be edited.
7.
Enter the desired value and press the "Accept" softkey.
Edit PLC user program (828D only)
23.4 Displaying and editing PLC signals in the status list
Milling
Operating Manual, 08/2018, 6FC5398-7CP41-0BA0