14.19
RS-232-C
14.19.1
Reading-in and reading-out archives via a serial interface
You have the option of reading out and reading in archives in the "Program manager" operating
area as well as in the "Startup" operating area via the V24 serial interface.
Availability of the V24 serial interface
If you want to change the availability of the V24 interface, you can adjust the following
parameters in file "slpmconfig.ini”:
Parameters
Description
[V24]
Describes the section in which the relevant setting parameters
are located.
useV24
Setting for the availability of the V24 serial interface
= true
Interface and softkeys are available (de‐
fault)
= false
Interface and softkeys are not available
Storage of file "slpmconfig.ini"
The template of the file "slpmconfig.ini" for SINUMERIK Operate is stored in the following
directory:
<Installation path>/siemens/sinumerik/hmi/template/cfg
Copy the file to one of the following directories:
<Installation path>/user/sinumerik/hmi/cfg
<Installation path>/oem/sinumerik/hmi/cfg
Note
If you want to achieve a better overview of the changes you have made yourself, simply delete
the unchanged parameters from the file copy "slpmconfig.ini".
Reading-out archives
The files to be sent (directories, individual files) are zipped in an archive (*.arc). If you send
an archive (*.arc), this is sent directly without being additionally zipped. If you have selected
an archive (*.arc) together with an additional file (e.g. directory), then these are zipped into a
new archive and are then sent.
Managing programs
14.19 RS-232-C
Milling
Operating Manual, 08/2018, 6FC5398-7CP41-0BA0
801