If the cursor is positioned on "Network x", a new, empty network is inser‐
ted behind this network.
5.
Position the cursor on the desired element below the network title and
press the "Insert operation" softkey.
The "Insert Operation" window appears.
6.
Select a bit operation and press the "OK" softkey.
7.
Press the "Insert operand" softkey.
8.
Enter the logic operation or the command and press the <INPUT> key to
complete the entry.
9.
Position the cursor on the operation that you want to delete and press
the "Delete operation" softkey.
- OR -
Position the cursor on the title of the network that you want to delete and
press the "Delete network" softkey.
- OR -
Press the <DEL> key.
The network, including all the logic operations and operands and/or the
selected operation is deleted.
23.5.8.5
Editing network properties
You can edit the network properties of a block.
Network title and network comment
The title can have a maximum of 3 lines and 128 characters. The comment must not contain
more than 100 lines and 4096 characters.
Procedure
1.
The ladder diagram display (LAD) is open.
2.
Use the cursor keys to select the network that you want to edit.
Edit PLC user program (828D only)
23.5 View of the program blocks
Milling
Operating Manual, 08/2018, 6FC5398-7CP41-0BA0
919