Remote control commands
R&S
®
SMM100A
996
User Manual 1179.1341.02 ─ 05
AUTO [IMMediate]
Executes a sweep automatically.
In this free-running mode, the trigger condition is met continu-
ously. I.e. when a sweep is completed, the next one starts imme-
diately.
SINGle [BUS]
Executes one complete sweep cycle.
The following commands initiate a trigger event:
[:SOURce<hw>]:SWEep:POWer:EXECute
[:SOURce<hw>]:SWEep[:FREQuency]:EXECute
:TRIGger<hw>[:SWEep][:IMMediate]
Set the sweep mode with the commands:
[:SOURce<hw>]:SWEep:POWer:MODE
[:SOURce<hw>]:SWEep[:FREQuency]:MODE
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:MODE
AUTO|STEP
In step mode (
STEP
), the instrument executes only one step.
EXTernal
An external signal triggers the sweep.
EAUTo
An external signal triggers the sweep. When one sweep is fin-
ished, the next sweep starts.
A second trigger event stops the sweep at the current frequency,
a third trigger event starts the trigger at the start frequency, and
so on.
*RST:
AUTO
Example:
See
Usage:
Setting only
:TRIGger<hw>:FSWeep[:IMMediate]
:TRIGger<hw>:LFFSweep:IMMediate
:TRIGger<hw>:PSWeep[:IMMediate]
:TRIGger<hw>[:SWEep][:IMMediate]
Performs a single sweep and immediately starts the activated, corresponding sweep:
●
FSWeep
- RF frequency
●
PSWeep
- RF level
●
LFFSweep
- LF frequency
●
SWEep
- all sweeps
Effective in the following configuration:
●
TRIG:FSW|LFFS|PSW|[:SWE]:SOUR
SING
●
SOUR:SWE:FREQ|POW:MODE
AUTO
or
SOUR:LFO:SWE:[FREQ:]MODE
AUTO
TRIGger subsystem