Remote control commands
R&S
®
SMM100A
765
User Manual 1179.1341.02 ─ 05
Example:
See
Example "Perform pulse modulation"
Manual operation:
See
[:SOURce<hw>]:PULM:DOUBle:DELay
<Delay>
Sets the delay from the start of the first pulse to the start of the second pulse.
Parameters:
<Delay>
float
*RST:
1E-6
Example:
See
Example "Perform pulse modulation"
Manual operation:
See
[:SOURce<hw>]:PULM:DOUBle:WIDTh
<Width>
Sets the width of the second pulse.
Parameters:
<Width>
float
Increment: 5E-9
Example:
See
Example "Perform pulse modulation"
Manual operation:
See
[:SOURce<hw>]:PULM:DOUBle:STATe
<State>
Provided for backward compatibility with former Rohde
&
Schwarz signal generators.
DOUBle
.
Parameters:
<State>
1 | ON | 0 | OFF
*RST:
0
[:SOURce<hw>]:PULM:STATe
<State>
Activates pulse modulation.
Parameters:
<State>
1 | ON | 0 | OFF
*RST:
0
Example:
See
Example "Perform pulse modulation"
Manual operation:
See
SOURce subsystem