Parameters:
<Deviation>
float
The value range depends on the symbol rate.
Range:
1 to 40E6
Increment: 0.5
*RST:
135416.5
Example:
SOURce:BB:DM:FORMat FSK4
SOURce:BB:DM:FSK:DEViation 1MHZ
Manual operation:
See
[:SOURce<hw>]:BB:DM:FSK:VARiable:SYMBol<ch0>:DEViation
<Deviation>
Sets the deviation of the selected symbol for variable FSK modulation mode.
Parameters:
<Deviation>
float
The value range depends on the selected symbol rate (see data
sheet).
Range:
-40E6 to 40E6
Increment: 0.5
Default unit: Hz
Example:
SOURce:BB:DM:FORMat FSKVar
SOURce:BB:DM:FSK:VARiable:TYPE FSK4
SOURce:BB:DM:FSK:VARiable:SYMBol0:DEViation 135000
Manual operation:
See
[:SOURce<hw>]:BB:DM:FSK:VARiable:TYPE
<Type>
The command selects the modulation type for Variable FSK.
Parameters:
<Type>
FSK4 | FSK8 | FSK16
*RST:
FSK4
Example:
See
[:SOURce<hw>]:BB:DM:FSK:VARiable:
Manual operation:
See
[:SOURce<hw>]:BB:DM:APSK16:GAMMa
<Gamma>
Sets the gamma function
γ
for the 16APSK modulation.
Parameters:
<Gamma>
G2D3 | G3D4 | G4D5 | G5D6 | G8D9 | G9D10
GxDy
: G = Gamma function,
xy
= code rate
*RST:
G2D3