Remote control commands
R&S
®
SMM100A
908
User Manual 1179.1341.02 ─ 05
Parameters:
<Voltage>
float
Range:
dynamic (see data sheet)
Increment: 0.001
*RST:
1
Default unit: V
Example:
SOURce:LFOutput1:VOLTage 1.5
Manual operation:
See
[:SOURce<hw>]:LFOutput<ch>:SHAPe
<Shape>
Selects the waveform shape of the LF signal.
Parameters:
<Shape>
SINE | SQUare | PULSe | TRIangle | TRAPeze
*RST:
SINE
Example:
See
Example "Configuring the LF generator"
Options:
TRIangle|TRAPeze require R&S
SMM-K24
Manual operation:
See
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:DCYCle
<DCycle>
Sets the duty cycle for the shape pulse.
Parameters:
<DCycle>
float
Range:
1E-6 to 100
Increment: 1E-6
*RST:
50
Default unit: PCT
Example:
See
Example "Configuring the LF generator"
Manual operation:
See
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:PERiod
<Period>
Sets the period of the generated pulse. The period determines the repetition frequency
of the internal signal.
Parameters:
<Period>
float
Range:
1E-6 to 100
Increment: 1E-8
*RST:
1E-3
Example:
See
Example "Configuring the LF generator"
SOURce subsystem