Configuring the internal baseband source
R&S
®
SMM100A
174
User Manual 1179.1341.02 ─ 05
They can be inserted after the
TYPE
tag in arbitrary order.
An example of the control list file contents could be:
{TYPE:SMU-CL}{COPYRIGHT:Rohde&Schwarz}
{DATE:2012-06-11;15:00:09}{HOP LIST:0:0;498:1;506:0}
{CW MODE LIST:0:0;380:1}{LEVATT LIST 3:0:0;464:1}
{BURST LIST:0:0;122:1;270:0;582:1;924:0}
{MARKER LIST 4:0:0;706:1;764:0}
{MARKER LIST 3:0:0;530:1;633:0}
{MARKER LIST 2:0:0;350:1;457:0}
{MARKER LIST 1:0:0;108:1;160:0}
{CONTROL LENGTH:1000}
The
shows the representation of the created control list in the "Control
Data Editor".
Compare the displayed ramp values of "Marker 1" and the "Total List Length" with
the values in the corresponding tags.
Note:
In the provided example, the tags have been separated by line breaks for
better reading.
See also
Example "How to assign and activate control signals from a control list"
To create a control list in binary format
Generation of a control list in binary format is not necessary but possible.
► Use the commands
BB:DM:CLISt:...
to generate a control list in binary format
(see
on page 789 and the example in
Example "How to assign and activate control signals from a control list"
Using the arbitrary waveform generator (ARB)