Remote control commands
R&S
®
SMM100A
734
User Manual 1179.1341.02 ─ 05
TM<ch>
1|2|3
Determines the local connector, where:
SOURce1:INPut:TM1|2|3
= TMC1/2/3 of Baseband A/C and
SOURce2:INPut:TM1|2|3
= TMC4/5/6 of Baseband B/D
Parameters:
<Signal>
TRIGger | CLOCk | FEEDback | DATA
CLOCk
is available only for
TM1
DATA
is available only for
TM2
FEEDback
is available only for
TM2
Manual operation:
See
:OUTPut<hw>:TM<ch>:SIGNal
<Signal>
Determines the control signal that is output at the selected connector.
To define the connector direction, use the command
.
Suffix:
OUTPut<hw>
.
1 | 2
Determines the baseband the connectors belong to, where:
OUTPut1
= Baseband A/C or Baseband 1/3
OUTPut2
= Baseband B/D or Baseband 2/4
TM<ch>
1|2|3
Determines the local connector, where:
OUTPut1:TM1|2|3
= TMC1/2/3 of Baseband A/C or 1/3 and
OUTPut2:TM1|2|3
= TMC4/5/6 of Baseband B/D or 2/4
Parameters:
<Signal>
MARKA1 | MARKA2 | MARKA3 | SCLA | LATTA | BGATA |
HOPA | CWMODA | TRIGA | MARKB1 | MARKB2 | MARKB3 |
SCLB | LATTB | BGATB | HOPB | CWMODB | TRIGB |
MARKC1 | MARKC2 | MARKC3 | SCLC | LATTC | BGATC |
HOPC | CWMODC | TRIGC | MARKD1 | MARKD2 | MARKD3 |
SCLD | LATTD | BGATD | HOPD | CWMODD | TRIGD
MARKA1|MARKC1|MARKA2|MARKC2|(MARKA3|MARKC3)
=
Baseband A/C Marker 1/2/(3)
SCLA|SCLB|SCLC|SCLD
= Symbol Clock A/B/C/D
LATTA|LATTB|LATTC|LATTD
= Lev Att A/B/C/D
BGATA|BGATB|BGATC|BGATD
= Burst Gate A/B/C/D
HOPA|HOPB|HOPC|HOPD
= HOP A/B/C/D
CWMODA|CWMODB|CWMODC|CWMODD
= CW/Mod A/B/C/D
TRIGA|TRIGB|TRIGC|TRIGD
= Triggered A
The character A/B/C/D in the parameter value indicates the
baseband the signal is related to.
*RST:
depends on TM suffix
SOURce subsystem