Remote control commands
R&S
®
SMM100A
959
User Manual 1179.1341.02 ─ 05
Manual operation:
See
[:SOURce<hw>]:SWEep:COMBined:DWELl
<Dwell>
Sets the dwell time for the combined frequency / level sweep.
Parameters:
<Dwell>
float
Range:
0.01 to 100
Increment: 100E-6
*RST:
0.01
Example:
See
Example "Setup an RF frequency or power sweep"
[:SOURce<hw>]:SWEep:COMBined:EXECute
Executes an RF frequency / level sweep cycle.
The command triggers one single sweep manually. Therefore, you can use it in manual
sweep mode, selected with the command
[:SOURce<hw>]:SWEep:COMBined:MODE
.
Example:
See
Example "Setup an RF frequency or power sweep"
Usage:
Event
[:SOURce<hw>]:SWEep:COMBined:MODE
<SweepCombMode>
Sets the cycle mode for the combined frequency / level sweep.
Parameters:
<SweepCombMode> AUTO | MANual | STEP
AUTO
Each trigger event triggers exactly one complete sweep.
MANual
The trigger system is not active. You can trigger every step indi-
vidually by input of the frequencies with the commands
STEP
Each trigger event triggers one sweep step.
*RST:
AUTO
Example:
See
Example "Setup an RF frequency or power sweep"
SOURce subsystem