Remote control commands
R&S
®
SMM100A
850
User Manual 1179.1341.02 ─ 05
Parameters:
<CarrierIndex>
integer
Range:
0 to lastCarrier
<State>
1 | ON | 0 | OFF
*RST:
0
Example:
See
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:CARRier:LIST:STATe
<Stat0[,Stat1..]>]
[:SOURce<hw>]:BB:MCCW:CARRier:LIST:STATe?
<Start>, <Count>
Switches the carrier on or off with the aid of a value list.
The first value in the list is assigned to the carrier with index 0, the second value to the
carrier with index 1, etc. The maximum length corresponds to the maximum number of
multi carriers. There is no need to enter all the values every time. Values not set by the
value list are set with the default values provided they have already been explicitly set
by a previous command. If this is the case, the values continue to apply until overwrit-
ten.
Setting parameters:
<Stat0[,Stat1..]>
ON | OFF
Query parameters:
<Start>
integer
start carrier index
Range:
0 to lastCarrier
<Count>
integer
number of carriers in the carrier range, starting from the
<Start>
carrier
Range:
1 to lastCarrier
Return values:
<State[,State..]>
select
Example:
See
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:CARRier:PHASe
<CarrierIndex>, <Phase>
For disabled optimization of the crest factor, sets the start phase of the selected carrier.
Parameters:
<CarrierIndex>
integer
Range:
0 to lastCarrier
SOURce subsystem