<Seg>
Sweep segment number. This suffix is ignored.
Parameters:
<Boolean>
ON
–
use independent GC settings, to be defined via
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol
OFF
–
reset the GC mode in all sweep segments to the GC
mode for unsegmented sweeps, defined via
. ON will not restore the previous val-
ues.
*RST:
ON
Example:
See
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol
Manual operation:
See
[SENSe<Ch>:]SEGMent<Seg>:POWer[:LEVel]:CONTrol
<Boolean>
Selects common or independent internal source "Power" settings for the sweep seg-
ments.
Suffix:
<Ch>
.
Channel number
<Seg>
Sweep segment number. This suffix is ignored; the setting con-
trols the whole segmented sweep.
Parameters:
<Boolean>
ON
–
use independent power settings, to be defined via
[SENSe<Ch>:]SEGMent<Seg>:POWer[:LEVel]
OFF
–
reset the power in all sweep segments to the power for
unsegmented sweeps, defined via
POWer<PhyPt>[:LEVel][:IMMediate][:AMPLitude]
will not restore the previous values.
The parameter is automatically switched to
ON
when a segment
power is entered using
*RST:
OFF
Example:
SEGM:ADD
Create a new sweep segment no. 1 in channel no. 1 using
default settings and thus -10 dBm internal source power.
SEGM:POW -20
Decrease the power to -20 dBm.
SEGM:POW:CONT OFF
Couple the powers in all segments and reset the power in seg-
ment no. 1 to the initial value.
Manual operation:
See