Parameters:
<IFConversionMode> DCUPper | DCLower | UCONversion | BAND1 | BAND2
DCUPper | BAND2
–
IF = RF - LO (down conversion upper side-
band, equivalent to BAND2)
DCLower | BAND1
–
IF = LO - RF (down conversion lower side-
band, equivalent to BAND1)
UCONversion
–
IF = LO + RF (up conversion)
*RST:
DCUPper
Example:
*RST; FREQ:CONV:MIX:LOF 3 GHz
Reset the analyzer and specify a fixed frequency of 1 GHz, to be
assigned to the LO signal.
FREQ:STAR 1 GHz; STOP 2 GHz
Define a sweep range between 3 and 4 GHz, to be assigned to
the RF signal.
FREQ:CONV:MIX:TFR DCL
Select down conversion to the lower sideband, corresponding to
an IF frequency range between 2 GHz and 1 GHz.
Manual operation:
See
[SENSe<Ch>:]FREQuency:IMODulation:CONVersion
<OFF>
Disables the intermodulation measurement and switches back to normal mode (no fre-
quency conversion).
Suffix:
<Ch>
.
Channel number
Setting parameters:
<OFF>
OFF
Disable intermodulation measurement
*RST:
n/a
Example:
See
[SENSe<Ch>:]FREQuency:IMODulation:LTONe
Usage:
Setting only
[SENSe<Ch>:]FREQuency:IMODulation:LTONe
<SourceType>[, <SourceNumber>]
Selects the source for the lower tone signal that is used for the intermodulation mea-
surement.
Suffix:
<Ch>
.
Channel number
Parameters:
<SourceType>
PORT
Lower tone source; internal source at port <arg1>
SCPI Command Reference