![Rohde & Schwarz 1332.4500.22 User Manual Download Page 790](http://html1.mh-extra.com/html/rohde-and-schwarz/1332-4500-22/1332-4500-22_user-manual_1477782790.webp)
Command Reference
R&S
®
ZNA
790
User Manual 1178.6462.02 ─ 12
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
*RST:
OFF
Options:
R&S
ZNA-K20
Manual operation:
See
CALCulate<Chn>:EYE:STATe
<Boolean>
Defines whether the active trace in the selected channel shall be represented as an
eye diagram.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
Example:
*RST
// switch trace to to S31 and switch on the eye diagram
:CALCulate1:PARameter:MEASure 'Trc1', 'S31'
CALCulate1:EYE:STATe ON
Options:
R&S
ZNA-K20
Manual operation:
See
CALCulate<Chn>:EYE:STIMulus:ENCoder
<Boolean>
in the bit stream simulation of the related eye dia-
gram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
*RST:
OFF
Options:
R&S
ZNA-K20
Manual operation:
See
CALCulate<Chn>:EYE:STIMulus:LOWPass
<Boolean>
Enables/disables a single pole low pass filter in the binary signal generator simulation
of the related eye diagram measurement.
SCPI Command Reference