Command Reference
R&S
®
ZNA
1175
User Manual 1178.6462.02 ─ 12
Suffix:
<Ch>
.
Channel number
Setting parameters:
<Mode>
LDIStortion | LNOise
LDIStortion
0 dB gain, for high input levels
LNOise
10 dB gain, for low input levels
*RST:
LDIStortion
Example:
*RST; :SENSe:POWer:GAINcontrol:GLOBal MANual
Enable the manual configuration of independent GC settings for
each drive port.
SENSe:POWer:GAINcontrol:ALL LNO
Set the GC mode of all a and b wave receivers to "Low Noise".
Usage:
Setting only
Manual operation:
See
[SENSe<Ch>:]POWer:GAINcontrol:GLOBal
<GCModesGlobal>
Globally configures the gain control (GC) in all receive paths (measurement receivers,
b-waves) for all analyzer ports or enables port-specific gain control configuration.
Suffix:
<Ch>
.
Channel number
Parameters:
<GCModesGlobal>
LNOise | LDIStortion | MANual
LDIStortion
0 dB gain, for high input levels
LNOise
10 dB gain, for low input levels
MANual
Enables the manual configuration of independent wideband /
narrowband IF gain settings for each segment, drive port and
receiver. See
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol
*RST:
LDIS
Example:
See
Manual operation:
See
8.3.14.21
[SENSe:]PULSe...
Pulsed measurements.