69
Trigger Inputs and Output Format
Section 4-3
11
Host Link
Read source data
area
0: IR/CIO, 1: HR, 2: LR, 3: DM, 4: None
12
Start address
0000 to 9995 (See note 2.)
13
Write destination data
area
0: IR/CIO, 1: HR, 2: LR, 3: DM, 4: None
14
Start address
0000 to 9996 (See note 2.)
15
PLC mode check
0: ON, 1: OFF
16
Terminal block
Trigger mode
0: Continuous, 1: Level trigger
17
Output polarity
0: ON for NG, 1: ON for OK
18
Output period
000020 to 100000 in 100-
m
s units
(See note 3.)
19
Gate ON delay
00010 to 10000 in 100-
m
s units
(See note 4.)
20
Gate ON time
00010 to 10000 in 100-
m
s units
(See note 4.)
21
Output settings Attach number of dig-
its
0: OFF, 1: ON
22
Attach center coordi-
nates
0: OFF, 1: ON
23
Attach rotational
angle
0: OFF, 1: ON
24
Polling
0: OFF, 1: ON
25
Data region specifica-
tion function
0: OFF, 1: ON
26
Start position
001 to 999 (See note 1.)
27
End position
001 to 999 (Must be greater than the start
position. See note 1.)
28
Image storage
method
Image storage
0: None, 1: Only NG, 2: All
29
Startup mode
Start scene
0 to 9
30
Start mode
0: SET, 1: MON, 2: RUN
31
Error method
BUSY input
0: OFF, 1: ERR ON
32
Device settings Two-camera Unit
0: Out of use, 1: F150-A20
33
Camera 0 Intelligent
Light Source
0: Out of use, 1: F150-SLC20,
2: F150-SLC50
34
Camera 1 Intelligent
Light Source
0: Out of use, 1: F150-SLC20,
2: F150-SLC50
Number
System data
Summary of Contents for V530-R150E-3 -
Page 7: ......
Page 9: ......
Page 17: ......
Page 27: ......
Page 47: ......
Page 63: ......
Page 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Page 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Page 263: ......
Page 279: ......
Page 281: ......
Page 283: ......
Page 289: ......