196
System
Section 6-4
Host Link
When Host link is selected for the communications mode, it is possi-
ble to communicate with host devices such as Programmable Con-
troller with host link format via RS-232C.
MON (Monitor) Mode
Receives command inputs, but the reading results are not output.
RUN Mode
Possible to input commands and output the reading results.
1,2,3...
1.
Set the area from which the V530-R150 reads commands. Select
I/O, HR (holding relay), LR (link relay), DM (data memory), or
None. If None is set, the TXD instruction and terminal block inputs
will still be accepted. (The default setting is I/O.)
2.
Set the first word to read in area specified above (0 to 9995).
(Default setting: 0)
3.
Set the write area where the V530-R150 writes the result.
Select I/O, HR (holding relay), LR (link relay), DM (data memory),
or None (No writing). (The default setting is I/O.)
4.
Set the first word to write in the area specified (0 to 9996).
(Default setting: 100)
5.
Select whether to check the Programmable Controller’s operating
mode.
ON: Checks the mode of the Programmable Controller in MON
(monitor) and RUN modes. Reading does not start unless
the Programmable Controller is in MONITOR mode. Error
messages are displayed.
(Default setting)
OFF: When the V530R150 is in Monitor or Run mode, it sends a
mode change command to the Programmable Controller to
Summary of Contents for V530-R150E-3 -
Page 7: ......
Page 9: ......
Page 17: ......
Page 27: ......
Page 47: ......
Page 63: ......
Page 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Page 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Page 263: ......
Page 279: ......
Page 281: ......
Page 283: ......
Page 289: ......