97
Connection Examples
Section 4-5
Connection 4
The wiring required between the host and the NT-AL001 is shown
below.
V530-R150 Settings
1,2,3...
1.
Go into system mode and select Multi drop.
2.
The following screen will be displayed. Set each of the displayed
items.
3.
Select End.
Process Flow
• Set the unit numbers for each of the V530-R150s.
(In this example, the unit numbers are set to 00, 01, and 02.)
• After the V530-R150 reads a code, it holds the data without out-
putting it. Polling commands are sent out in order from the host
and the data is downloaded.
Host
NT-AL001
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
SG (GND)
Pin No.
*
*
*
*
*
Meaning
Send data
Receive data
Request to send
Clear to send
Power supply (+5 V)
Signal ground
5 V
power
supply
Pin No.
2
3
4
5
6
9
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
+5 V
SG (GND)
Set this to "ON."
Set the unit number (00 to 31).