34
Specifications
Section 3-1
There are 3 kinds of COM OUT (*1 to *3) for each output terminal.
Connect with reference to the following table.
Table A
Table B
Note
1.
Do not reverse the connections of the signal terminals and COM
terminals.
2.
Do not use RESET input immediately after power is turned ON.
When using RESET input to synchronize execution timing, wait at
least 1 s after turning ON the V530-R150 power supply before
turning ON the RESET terminal.
Top
Bottom
+
Power supply
NC
Not connected
–
Appropriate ground
RUN
Control output
ERR
Error output
BUSY
GATE
Control output
OK/NG
Judgment output
NC
Not connected
COM OUT (*1)
For RUN, ERR, BUSY,
GATE, and OK/NG
RESET
Restart
TRIG A
Trigger input (One shot
mode)
DSA
Do not use
TRIG B
Trigger input (Continuous
or Level Trigger mode)
COM IN
Top
Bottom
DO 1
Coincidence output
DO 0
Coincidence output
DO 3
DO 2
DO 5
Do not use
DO 4
Do not use
DO 7
DO 6
NC
Not connected
COM OUT (*2)
For DO 0 to DO 7
DO 9
Do not use
DO 11
DO 8
Do not use
DO 13
DO 10
DO 15
DO 12
DO 14
COM OUT (*3)
For DO 8 to DO 15
Summary of Contents for V530-R150E-3 -
Page 7: ......
Page 9: ......
Page 17: ......
Page 27: ......
Page 47: ......
Page 63: ......
Page 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Page 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Page 263: ......
Page 279: ......
Page 281: ......
Page 283: ......
Page 289: ......