256
Error Codes and Countermeasures
Section 9-2
Common Check Items for Error Codes E160 to E182
• Check that the code is not rotated at an angle of more than
10
when compared to the registered model.
• Check that the Matrix size is set correctly.
• Check that the model has been registered correctly using the
Reference Model procedure given on page 152.
E180
E181
E182
Decode error
An L-shape finder pattern was detected but the data
could not be decoded.
• The data part of the code may be stained or damaged.
Check the condition of the data part of the code.
• Model registration may not have been performed in the
optimum way. Re-register the model with reference to
page 152.
• The cell recognition coordinates may be incorrect.
Adjust the field of vision so that the code image is
larger and re-enter the settings.
E200
Timeout error
Decoding was not performed within the timeout time.
• Perform teaching or register the pattern again to
change and improve the settings.
• Set a longer timeout time.
Error Code
Description
Countermeasures